Chapter 3: CLI Appliance Settings Options 37

To enable and assign the Serial profile to a serial port:

1.

Enter

cd appliance_settings/ports/physical_ports/serial_ports/<n>/port_settings

to

navigate to the ports_settings level. Port 3 is used in the example.

--:- units cli-> cd appliance_settings/ports/physical_ports/

serial_ports/3/port_settings

2.

Enter

show

. A listing similar to the following appears.

--:- port_settings cli-> show

port_settings

port = 3

status = disabled

rj45_pin-out = cyclades

serial_profile = unconfigured

communication_settings

speed = 9600

parity = none

data_bits = 8

stop_bits = 1

flow_control = none

NOTE: Serial_Profile choices are cas, dial-in or power.

3.

Enter

set port_settings/ status=enabled serial_profile=cas

to enable the port and assign it

the CAS Serial Profile. Enter

commit

to save the change.

ppp_connection =

ppp|pap_authentication =

devices

secure_dial-in

callback_users

ppp_otp_users

power_profile