Appliance_settings/global_settings, Table 3.1: global settings options – Avocent Advanced Console Server ACS 6000 User Manual
Page 38
![background image](/manuals/39578/38/background.png)
28 Cyclades ACS 6000 Advanced Console Server Command Reference Guide
See Table 3.1 through Table 3.13 for options available at each level and their default settings,
where applicable. Parameters with an X beside them were selected, either as the default or from the
previous configuration.
Appliance_Settings/Global_Settings
1.
Enter
cd appliance_settings/global_settings
to navigate to the Global Settings level.
--:- units cli-> cd appliance_settings/global_settings
2.
Enter
show
to view the available options.
--:- global_settings cli-> show
global_settings
sessions/
sensors/
data_buffering/
3.
Enter
show
followed by an option name to view information about each option.
--:- global_settings cli-> show sessions
Table 3.1: Global Settings Options
Global Settings Navigation Tree
sessions
idle_timeout = 300 (default)
[ ] enable_session_logging
destination = local (default)
timestamp = no (default)
[ ] enable_session_logging_alerts (none configured)
string_1 =
string_2 =
string_3 =
string_4 =
string_5=
string_6 =
string_7 =
string_8 =