Figure 39 add dkc pane, 39 add dkc pane – HP StorageWorks XP Remote Web Console Software User Manual

Page 81

Advertising
background image

Continuous Access XP Journal user guide

81

• Remote disk array’s serial number.
• Remote disk array’s controller ID.

NOTE:

The controller ID for an XP10000/XP12000 disk array is 4.

• Path group ID. The path group ID is within the range of 1-FF (hexadecimal). Up to 64 path group

IDs can be registered per disk array.

NOTE:

In the current version, the path group IDs always take the default values and cannot be

changed.

8.

In the Add DKC pane, select a primary and remote disk array port to configure a logical path.

9.

Click Option.

10.

In the DKC Option pane, configure logical path and disk array options. For more information about the

options, see ”

Changing options for logical paths and disk arrays

” on page 82.

11.

Click Set to close the DKC Option pane.

12.

In the Preset list, check the settings you made.
• To modify a setting, select and right-click the setting from the Preset list, and select Modify. A pane

appears where you can modify the setting.

• To cancel a setting, select and right-click the setting in the Preset list, and select Cancel.

13.

Click Apply to apply the settings.

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view

detailed information about the error, right-click the error code, and select Error Detail. An error

message appears providing detailed information about the error.

Figure 39

Add DKC pane

The Add DKC pane displays the following:

•

DKC S/N: Enter the remote disk array’s five-digit serial number.

•

Controller ID: Enter the remote disk array’s controller ID (that is, disk array family ID).

Advertising