6 nonstop autotmf software commands, Running the command interpreter, Nonstop autotmf software commands – HP NonStop G-Series User Manual

Page 75

Advertising
background image

HP NonStop AutoTMF Software User’s Guide429952-014

6-1

6

NonStop AutoTMF Software
Commands

The command interpreter (CI) is the primary interface for installing, configuring,
controlling and monitoring NonStop AutoTMF software.

This chapter describes the command interpreter and is organized as follows:

Running the Command Interpreter

Command Syntax

Command Summary

Command Descriptions

Monitor Commands

Running the Command Interpreter

Use this TACL RUN command to start the command interpreter:

run-options

process options for any TACL RUN command.

monitor

If an alternate monitor is configured, specifies the name of the alternate monitor
process. The monitor process name must be a local name, starting with a dollar
sign (“$”).

cmd

specifies a command.

The CI sets the completion code when the CI stops. The completion code values are:

0: Normal completion

1: Warnings messages were issued during the session

2: Error messages were issued during the session

During a CI session, you can display the completion code by using the

ENV

command.

Use the

RESET

command to restore the completion code to 0. The RESET command

also restores all parameters displayed by the ENV command to their default values.

[RUN] $SYSTEM.ESCORT.ESCORT[/run-options/] [monitor;] [cmd]