Configuring the Virtual Connect domain using the CLI 145

You can remove connections at any time (one at a time, from the bottom).

If the existing profile connections do not match the current FC/FCoE module configurations, the add
operation is not allowed.

The current maximum number of FC/FCoE connections is four per I/O bay.

The following table lists several scenarios that describe how adding FC/FCoE connections affects an existing

profile. The scenarios are true for FC module configurations and FC modules, as well as FCoE module

configurations and FCoE-capable modules.

Scenario

Description

Existing profile

connections

Current FC module

configurations

Adding profile

connections

1

Start with modules in Bays
3 and 4, create a profile,

then edit the profile and

add connections.

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Add connection, 2 times

2

Start with modules in Bays

3–6, create a profile, then
edit the profile and add

connections.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4
Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Add connection, 4 times

3

Start with modules in Bays

3 and 4, create a profile,
hotplug modules into Bays

5 and 6, then edit the

profile and add
connections.

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4
Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Add connection, 2 times

4

Start with modules in Bays

3 and 4, create a profile

(add 2 connections),
hotplug modules into Bays

5 and 6, then edit the

profile.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the
profile.

This profile is not useful

after the hotplug. To
resolve this issue, delete

connections 3 and 4,

save the profile, and then
scenario 3 applies.

5

Start with modules in Bays

3–6, create a profile,

hotplug modules into Bays
7 and 8, then edit the

profile and add

connections.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6
Bay 7 Bay 8

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 7

6

Bay 8

Add connection, 2 times