Item

Description

Avoid using duplicate trap destinations. Setting duplicate trap destinations can

result in duplicate traps being sent to the same destination, or only one of the trap
destinations being configured.

Syntax

add snmp-trap <Name> Address=<IPv4Address|DNSname>

[Community=<community name

string>][Format=<SNMPv1|SNMPv2>][Severity=<trap

severity|All|None>][DomainCategories=<domain trap

category|All|None>][EnetCategories=<enet trap

category|All|None>][FcCategories=<fc trap

category|All|None>]

Parameter

Name (required)

A unique name for the new trap being added

Properties

Address (required) IPv4 address or DNS name for the trap destination
Community (optional) The SNMP community name string for the specified trap. If not specified, the default

value is "public". For VC-Enet modules, the maximum string length is 39. For VC-FC

modules, the maximum string length is 24.

Format

Format of the new trap. Valid values are "SNMPv1" and "SNMPv2". If not
specified, the default is "SNMPv1".

Severities

Trap severities to send to the destination. Valid values are "Normal", "Unknown",

"Info", "Warning", "Minor", "Major", "Critical", "All", and "None". Multiple
severities can be specified, separated by commas. The default severity is "None".

DomainCategories

The Virtual Connect domain trap categories to send to the destination. Valid values

are "Legacy", "DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus",

"ServerStatus", "EnetStatus", FcStatus", "All", and "None". Multiple categories can
be specified, separated by commas.

EnetCategories

The Virtual Connect Ethernet trap categories to send to the destination. Valid values

are "PortStatus", "PortThreshold", "Other", "All", and "None". Multiple categories

can be specified, separated by commas.

FcCategories

The Virtual Connect Fibre Channel trap categories to send to the destination. Valid

values are "PortStatus", "Other", "All", and "None". Multiple categories can be

specified, separated by commas.

Examples

->add snmp-trap EnetManagementStation Address=192.112.34.10

Community=private Format=SNMPv1 Severity=Normal,Critical

EnetCategories=Other

Adds a new trap destination for VC-Enet modules

->add snmp-trap FcManagementStation Address=192.112.72.3

Community=private Format=SNMPv1 FcCategories=Other

Adds a new trap destination for VC-FC modules

->add snmp-trap MyTrap Address=192.112.66.12

Adds a new trap using typical defaults

->add snmp-trap MyTrap Address=192.112.42.5 Severity=All

FcCategories=All DomainCategories=All

Adds a trap with all severity and category properties set. Severities are allowed
even though FC categories are set, but the severities are applied to the domain

categories.

Item

Description

remove snmp-trap

Removes a previously configured SNMP trap destination.

Syntax

remove snmp-trap <Name|*>