HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 81

Command line 81
Item
Description
Avoid using duplicate trap destinations. Setting duplicate trap destinations can
result in duplicate traps being sent to the same destination, or only one of the trap
destinations being configured.
Syntax
add snmp-trap <Name> Address=<IPv4Address|DNSname>
[Community=<community name
string>][Format=<SNMPv1|SNMPv2>][Severity=<trap
severity|All|None>][DomainCategories=<domain trap
category|All|None>][EnetCategories=<enet trap
category|All|None>][FcCategories=<fc trap
category|All|None>]
Parameter
Name (required)
A unique name for the new trap being added
Properties
Address (required) IPv4 address or DNS name for the trap destination
Community (optional) The SNMP community name string for the specified trap. If not specified, the default
value is "public". For VC-Enet modules, the maximum string length is 39. For VC-FC
modules, the maximum string length is 24.
Format
Format of the new trap. Valid values are "SNMPv1" and "SNMPv2". If not
specified, the default is "SNMPv1".
Severities
Trap severities to send to the destination. Valid values are "Normal", "Unknown",
"Info", "Warning", "Minor", "Major", "Critical", "All", and "None". Multiple
severities can be specified, separated by commas. The default severity is "None".
DomainCategories
The Virtual Connect domain trap categories to send to the destination. Valid values
are "Legacy", "DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus",
"ServerStatus", "EnetStatus", FcStatus", "All", and "None". Multiple categories can
be specified, separated by commas.
EnetCategories
The Virtual Connect Ethernet trap categories to send to the destination. Valid values
are "PortStatus", "PortThreshold", "Other", "All", and "None". Multiple categories
can be specified, separated by commas.
FcCategories
The Virtual Connect Fibre Channel trap categories to send to the destination. Valid
values are "PortStatus", "Other", "All", and "None". Multiple categories can be
specified, separated by commas.
Examples
->add snmp-trap EnetManagementStation Address=192.112.34.10
Community=private Format=SNMPv1 Severity=Normal,Critical
EnetCategories=Other
Adds a new trap destination for VC-Enet modules
->add snmp-trap FcManagementStation Address=192.112.72.3
Community=private Format=SNMPv1 FcCategories=Other
Adds a new trap destination for VC-FC modules
->add snmp-trap MyTrap Address=192.112.66.12
Adds a new trap using typical defaults
->add snmp-trap MyTrap Address=192.112.42.5 Severity=All
FcCategories=All DomainCategories=All
Adds a trap with all severity and category properties set. Severities are allowed
even though FC categories are set, but the severities are applied to the domain
categories.
Item
Description
remove snmp-trap
Removes a previously configured SNMP trap destination.
Syntax
remove snmp-trap <Name|*>
Parameter
- 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem