Adding uplink ports to a shared uplink set, Creating a network that uses a shared uplink set, Server vlan tagging support – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 134

Advertising
background image

Configuring the Virtual Connect domain using the CLI 134

Summary for all shared uplink sets
>show uplinkset

Details for all shared uplink sets
>show uplinkset *

Details for a single shared uplink set
>show uplinkset MyUplinkSetName

Adding uplink ports to a shared uplink set

To add uplink ports to a shared uplink set, use the add uplinkport command:

>add uplinkport enc0:1:2 uplinkset=MyUplinkSetName

Creating a network that uses a shared uplink set

To create a network that uses a shared uplink set, use the add network command:

>add network MyNewNetworkName uplinkset=MyUplinkSetName vlanid=156

Creating multiple networks that use a shared uplink set

To create multiple networks that use a shared uplink set, use the add network-range command:

>add network-range UplinkSet=SUS1 VLANIds=

Server VLAN Tagging Support

Each server port can be connected to multiple virtual networks, each using a unique server VLAN ID for virtual

network mapping.
The translation of Server VLAN tags to internal network VLAN and again to external data center VLAN tags,

and the reverse, on incoming and outgoing frames can result in a configuration where the server VLANs

might not match the external VLANs used on uplinks. To avoid this scenario, the server connections can be
forced to use the same VLAN mappings as the shared uplink sets. Setting the value to "true" restricts the server

network connections to be selected from a single shared uplink, and the VLAN ID cannot be modified:

>set enet-vlan SharedServerVLanID=true

Setting the value to "false" enables you to select any VC Ethernet network for the server Ethernet connections,

and VLAN ID mappings can be modified to ensure uniqueness:

>set enet-vlan SharedServerVLanID=false

When using mapped VLAN tags, the overall link speed can be controlled as follows:

>set enet-vlan PrefSpeedType=Custom PrefSpeed=500 MaxSpeedType=Custom

MaxSpeed=2500

VLAN Capacity
Virtual Connect imposes certain limits on the number of networks (VLANs) in the domain and the server
connections carrying multiple VLANs. In a VC domain that does not contain legacy (1/10Gb) VC Ethernet

modules, these restrictions can be relaxed to provide support for more VLANs and enhance the flexibility of

mapping VLANs to server connections. When VCM detects that no legacy modules are present in the

domain, it enables the selection of a new domain mode that expands the VLAN capacity. The increase in the

number of VLANs per domain, in addition to the flexibility of allocating VLANs among the server connections
for a physical port, provides you with more options when configuring a Virtual Connect environment.