Configuring the Virtual Connect domain using the CLI 144

Removing a connection that is mapped to Flex-10

Assigning a profile to a server that maps Flex-10 connections

Unassigning a profile with Flex-10 connections

Flex-10 connection changes that do not require power off
With Virtual Connect Manager v2.10 and higher, it is not necessary to power off a server blade with Flex-10

connections in the following instances:

Changing a connection's network:

o

From a single network to another single network

o

From a single network to multiple networks

o

From multiple networks to a single network

Modifying the networks or VLAN IDs in a connection with multiple networks

With Virtual Connect Manager v2.30 and higher, it is not necessary to power off a server blade with Flex-10

connections in the following instances:

Changing a connection's network:

o

From "unassigned" to a single network

o

From a single network to "unassigned"

o

From "unassigned" to multiple networks

o

From multiple networks to "unassigned"

Changing the requested bandwidth

FCoE connection changes that require power off

Adding an FCoE connection to an assigned server profile

Removing an FCoE connection from an assigned server profile

Assigning a profile containing FCoE connections to a server

Changing FCoE boot parameters

Restart after OA credential recovery
The state, "profile recovered," is applied to servers that are powered on when VC Manager restarts after an
OA credential recovery. When VC Manager detects a restart after a credential recovery, it rewrites the

profile parameters for any server that is powered on, connects the server to the appropriate Ethernet networks

and FC fabrics, and then puts the server and profile in the "profile recovered" state. The server and profile

remain in the "profile recovered" state until the server is powered down or removed from the enclosure. This
feature eliminates the power cycle requirement for a server to recover.

General requirements for adding FC or FCoE connections

Adding FC and FCoE connections is generally allowed during profile add and edit operations. It is not

allowed in some specific cases. Observe the following general requirements:

When a profile is added, the FC/FCoE connections initially displayed are based on the FC/FCoE
module configuration in the domain, respectively. A pair of horizontally adjacent FC/FCoE-capable

modules has two connections.

Connections can only be added or removed from the bottom. You can only add or delete connections
at the end of the list.