Enet-connection – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 23

Advertising
background image

Command line 23

Item

Description

EnclosureID

(required)

The enclosure ID of the remote enclosure to be removed from the domain. Use "*"

to remove all remote enclosures in the domain. The enclosure IDs can be
identified for a particular enclosure by using the show enclosure command.

The local enclosure cannot be removed from the domain with this command.

Examples

->remove enclosure encl

Removes a remote enclosure

->remove enclosure *

Removes all remote enclosures from the domain

Item

Description

show enclosure

Display all enclosures in the domain.

Syntax

show enclosure [<EnclosureID>|*]

Parameter

EnclosureID

(optional)

The ID of an enclosure in the domain. If specified, only details for that enclosure

appear.

Examples

->show enclosure

Displays a summary of all enclosures

->show enclosure *

Displays detailed information for all enclosures

->show enclosure enc0

Displays detailed information for a specific enclosure

enet-connection

Manage Ethernet network connections.
Supported actions: add, help, remove, set, show

Item

Description

add enet-connection

Add a new Ethernet network connection to an existing server profile.

The maximum number of Ethernet connections that can be added to a
server profile is 128.

Syntax

add enet-connection <ProfileName>

[Network=<NetworkName>]

[PXE=<enabled|disabled|UseBios>]

[AddressType=<Factory-Default|User-Defined>]

[EthernetMAC=<MAC Address> iScsiMAC=<MAC Address>]

[SpeedType=<Auto|Preferred|Custom>] [Speed=<speed>]

Parameter

ProfileName (required)

The name of an existing profile to which the new connection is added

Properties

Network (optional)

The name of an existing network to associate with the connection. If the

network name is not specified, or is set to "unassigned", the network
remains unassigned and can be assigned later.

PXE (optional)

Enables or disables PXE on the network connection. Valid values are

"enabled", "disabled", and "UseBios". If not specified, the default is

"UseBios".
Only one connection can have PXE enabled per profile.

Advertising