8.

Use the Mirror drop-down lists to specify the following items sequentially:

Master journal group

Mirror ID

Restore journal group

9.

Do one of the following to make settings on the initial copy operation:

Select Entire if you want to start the initial copy operation immediately after the pair is
created.

Select None if you do not want to start the initial copy operation immediately after the
pair is created.

Select Delta if you want to create a URz pair for delta resync operation. You need to
meet the requirements listed in

“Requirements for Creating URz Pair for Delta Resync

Operation” (page 81)

.

10.

Use Error Level to specify the range used for splitting a pair when a failure occurs.

11.

Use CFW to specify whether to copy cache-fast-write data to the secondary data volume.

12.

Select Set to close the Add Pair window.

13.

See the Preview list in the Pair Operation window to check the settings that you have made.

To modify a setting, select and right-click the setting and then select Modify.

To cancel a setting, select and right-click the setting and then select Cancel.

14.

Select Apply to start pair creation and the initial copy operation. If an error occurs, the rightmost
column of the Preview list displays the error code. To view detailed information about the
error, right-click the error code and then select Error Detail. An error message appears and
gives you detailed information about the error.

15.

In the list of the Pair Operations window, verify that the status of the pair is correct.

If you selected Entire or None in step

10

, the status of the pair will be Pending or Duplex. If

you selected Delta, the status of the pair will be Hold.

16.

To monitor the progress of the Add Pair operation(s), click File, Refresh on the menu bar of
the XP Remote Web Console main window to update the information in the list, or use the
Detailed Information window (see

“Pair Status Panel” (page 147)

) to monitor the detailed status

of each pair.