Processor upgrade – HP ProLiant ML350p Gen8 Server User Manual

Page 53

Advertising
background image

Hardware options installation 53

o

For rack models, if removed, install the security bezel (on page

21

).

Processor upgrade

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

CAUTION:

To prevent possible server malfunction and damage to the equipment, multiprocessor

configurations must contain processors with the same part number.

CAUTION:

The heatsink thermal interface media is not reusable and must be replaced if the

heatsink is removed from the processor after it has been installed.

IMPORTANT:

Processor socket 1 must be populated at all times or the server does not function.

To remove the component:

1.

Do one of the following:

o

For tower models, open and remove the bezel ("

Remove the tower bezel

" on page

21

).

o

For rack models, if installed, remove the security bezel (on page

21

).

2.

Power down the server (on page

20

).

3.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

4.

Do one of the following:

o

For tower models, place the server on a flat, level surface with the access panel facing up.

o

For rack models, extend the server from the rack (on page

24

).

5.

Remove the access panel (on page

23

).

6.

Remove the air baffle (on page

25

).

Advertising