HP ProLiant DL180 Server User Manual
Page 43
Using LO100 43
o
On ML150 G5 servers:
i.
Press the down arrow (↓) key to scroll down to the Console Redirection option, and press the
Enter key.
ii.
Verify the following settings:
—
Console Redirection—Enabled
—
Baud Rate—115.2K
—
Terminal Type—VT100+
—
Flow Control—None
—
Redirection after BIOS POST—On
o
On DL160 G5 servers:
i.
Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii.
Verify the following settings:
—
Remote Access—Enabled
—
EMS support(SPCR)—Enabled
o
On DL165 G5 and DL185 G5 servers:
i.
Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii.
Verify the following settings:
—
Console Redirection—Enabled
—
EMS Support (SPCR)—Enabled
—
Serial Port Mode—09600 8,n,1
—
Flow Control—None
—
Redirection After BIOS POST—Always
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
o
On DL180 G5 servers:
i.
Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii.
Verify the following settings:
—
Remote Access—Enabled
—
EMS support(SPCR)—Enabled
—
Terminal Type—VT100
—
Flow Control—None
—
Redirection after BIOS POST—Always
o
On SL165z G6 servers:
i.
Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii.
Verify the following settings: