HP ProLiant DL180 Server User Manual
Page 45
Using LO100 45
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration—Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On HP ProLiant ML115 G5, ProLiant DL165 G5, and ProLiant DL185 G5 servers, verify the
following settings:
Configure Console Redirection
—
Console Redirection—Enabled
—
EMS Support (SPCR)—Enabled
—
Flow Control—None
—
Redirection After BIOS POST—Always
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration-Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On HP ProLiant DL120 G5 servers, verify the following settings:
Console Redirection
—
Console Redirection—Enabled
—
EMS support—Enabled
—
Baud Rate—115.2K
—
Terminal Type—VT100
—
Flow Control—None
—
Continue C.R. after POST—Enabled
I/O Device Configuration
—
Base I/O address—3F8
—
Interrupt—IRQ 4
o
On HP ProLiant ML150 G5 servers, verify the following settings:
Console Redirection
—
BIOS Serial console—Enabled
—
EMC Support (SPCR)—Enabled
—
Baud Rate—115.2K
—
Console Type—VT100
—
Continue C.R. after POST—On
I/O Device Configuration
—
Serial Port A—Enabled
—
Base I/O address—3F8
—
Interrupt—IRQ 4
o
On HP ProLiant DL160 G5 servers, verify the following settings: