Vcm shows an incorrect address for vcem – HP Insight Management-Software User Manual

Page 123

Advertising
background image

3.

Click Edit.

4.

In the boot target configurations table, change all the target LUN fields to be within the allowed
ranges (either a 3-digit decimal between 0-255, or a 16-digit hexadecimal between 0 and
FFFFFFFFFFFFFFFF).

5.

Click OK.

6.

Monitor the job progress until it is complete.

After the operation completes, you can perform move and failover operations on the server profile.

Error popup appears when you select HP predefined ranges during remove
VC Domain from group or delete VC Domain Group operations

Using the web browser in the Japanese language causes an error popup to appear when you
select a HP pre-defined range to be used by a VC Domain that is being removed from a VC Domain
Group.

To resolve the issue:
1.

Clear the Use Pre-defined range check box.

2.

Enter the From and To values for the desired range in the text boxes.

3.

Click OK. Wait until the process completes.

Unable to complete or cancel VC Domain maintenance after enabling
Expanded VLAN Capacity in VC Domains

VCEM 7.0 is able to manage VC Domains with Expanded VLAN capacity (Extended Mapped
VLAN) enabled, but Virtual Connect Manager implemented with firmware version 3.3x or later
does not allow you to easily revert back from Expanded VLAN capacity mode to Legacy capacity
mode.

Before applying Expanded VLAN capacity to a VC Domain 3.3x or later during Maintenance
Mode, make sure the VC Domain Group that the VC Domain belongs to is running firmware mode
3.3x or higher (this is a VCEM rule). If you change a VC Domain 3.3x to Expanded VLAN Capacity
and the Virtual Connect Domain Group firmware mode is lower than 3.3x, the Complete
Maintenance Mode operation will fail, because VCEM will detect an enabled feature (Expanded
VLAN capacity) not supported by the other VC Domains (with older firmware). The VC Domain
will remain in Maintenance Mode status and VCEM will not be able to complete or cancel the
maintenance operation. To complete or cancel the maintenance operation, you must first remove
the VC Domain with Expanded VLAN capacity from the Domain Group.

No error message when assigning a profile to a server with two FlexNIC
ports on the same physical NIC

VCEM does not report an error or warning message when assigning a profile to a server with two
FlexNIC ports on the same physical NIC. To avoid this situation, see the server profile details in
the VCM GUI to verify the results of the changes you have made and ensure that you do not have
a misconfiguration.

VCM shows an incorrect address for VCEM

When you log into the Virtual Connect Manager while under VCEM control, the following message
is displayed:

VC Domain locked by Virtual Connect Enterprise Manager [x.x.x.x]

The x.x.x.x in the message is an incorrect IP address for VCEM.

NOTE:

The incorrect IP address does not have any impact on VCEM management of VCM.

Leaving the incorrect IP address in place does not break any VCEM operations. The IP address is
only displayed to inform you that VCM is managed by VCEM from that IP address.