HP Insight Management-Software User Manual

Page 25

Advertising
background image

Table 4 MAC or WWN address and serial number range compatibility

VCEM-supported

MAC or WWN or serial number in VC
Domain Group

VC Domain server profiles with MAC
or WWN addresses or serial number
allocated as:

Yes

VCEM-defined or user-defined

VCEM-defined

Yes, as long as it belongs to the same
User-defined range

User-defined

User-defined

Yes, if a User-defined range is created
on VCEM

VCEM-defined

User-defined

Yes

Factory, VCEM-defined or
User-defined

Factory (MAC or WWN address)

Yes

VCEM-defined

HP-predefined

Yes, if a User-defined range is created
on VCEM

User-defined

HP-predefined

No

Factory

VCEM-Defined, HP-predefined, or
User-defined

VCEM validates the following components when adding a VC Domain to a VC Domain group,
therefore the VC Domain configuration must be identical to the VC Domain Group configuration.
Verify that the following components are identical:

•

Interconnect bays location and model

•

Enclosure model

•

Domain settings:

Configuration for double density servers (for example, BL2x220c)

◦

◦

Configuration for full-height and half-height single density servers (for example, BL460c,
BL480c)

•

Network Access Groups

◦

Name(s) and networks

•

Ethernet and iSCSI Flex-10 settings:

◦

MAC Cache Failover:

Enable Fast MAC Cache Failover

–

–

MAC Refresh Interval

◦

IGMP Snooping:

Enable IGMP Snooping

–

–

IGMP Idle Timeout Interval

◦

Server VLAN Tagging support:

Tunnel VLAN Taggings or Map VLAN Taggings

–

–

Force Server connection setting

◦

Multiple Network Speeding Settings:

Preferred Link Connections

–

–

Preferred Link Connection Speed

–

Maximum Link Connection

–

Maximum Link Connection Speed

Requirements for adding a VC Domain to a VC Domain Group