HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 108

Advertising
background image

Server management 108

Column name

Description

100Mb-MAX Configured speed for the network in 100-Mb increments.

PXE

Shows whether PXE is enabled, disabled, or USE BIOS is selected on that

port. Only one port can have PXE enabled for VC-controlled addresses.

MAC

Type of MAC address assignment configured for the Virtual Connect

domain

Delete When

the

X in the column is bold, this line item is eligible for deletion.

FC SAN Connections (Physical
ports)

Port

Relative order of the Fibre Channel port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module port connected to the server HBA port

Port speed

Speed of the VC-FC module port connected to the server HBA port

WWPN

Type of WWN address assignment configured for the Virtual Connect
domain

Delete When

the

X in the column is bold, this line item is eligible for deletion.

Assign Profile to Server Bay

Power

Icon indicates if the server blade is powered on or off (when a server

blade is selected)

Server Bay Assignment

Displays the enclosure name, bay number, and type of server blade

S/N

Serial number of the server blade in the device bay

Model

Model name of the server blade in the device bay

Status

Status of the server blade in the device bay

UID

Icon indicates if the server blade UID is on or off

The following table describes the available actions in the Define Server Profile screen. Clicking another

link in the pull-down menu or left navigation window causes current edits that have not been applied to be

lost.

Task Action

Create a profile name

Enter a name in the Profile Name field.

Select to use server factory
defaults for Ethernet MAC

addresses

Click Advanced....

Select to use server factory
defaults for Fibre Channel

WWNs

Click Advanced....

Select to use factory defaults for
serial numbers (logical)

Click Advanced....

Advertising