Interconnect Bay Overall Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot
be determined.

Check Onboard Administrator
communication.

(blue)

Initializing Device

is

initializing. Wait until initialization is complete.

(This icon should only be seen at

startup.)

(yellow

)

Degraded

Device is partially operational,
but capability is lost.

Check and correct the Onboard
Administrator error condition.

(orang
e)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager
configuration attributes.

(orang

e)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware.

Insert the correct module.

(orang

e)

No communication

Cannot communicate with the

device.

Check the physical connections and

IP address.

Missing

Device is configured but not
accessible.

Insert the correct hardware module.

Failed

Device is not operational because
of an error.

Reset the device or application, or
replace the device.

Interconnect Bay OA Reported Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot
be determined.

Check Onboard Administrator
communication.

(yellow

)

Degraded

Device is partially operational,

but capacity is lost.

Check and correct the Onboard

Administrator error condition.

Failed

Device is not operational because
of an error.

Check and correct the Onboard
Administrator error condition.