Enclosures view – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 19

Advertising
background image

HP Virtual Connect Manager 19

Possible cause: The management application running on the active VC-Enet module is an earlier version

than the backup VC-Enet module. If there is a failover to the backup module, the domain will lose its
redundancy because the later firmware on the current backup will upgrade the configuration database

and cause it to be unreadable by the earlier version.
Action: Upgrade the backup module to the same firmware version as is running on the active module. You

should also save the current configuration file immediately. Note that this state can also exist for a short
time during firmware upgrade, so if you are currently upgrading the firmware in your domain, you can

ignore this message.
VCM_OP_STATE_FW_INCOMPATIBLE_LESS_CAPABLE
Possible cause: The firmware running on this module is less capable than the firmware on the active VC-

Enet module. Some features might not work properly.
Action: Upgrade the firmware to the version running on the active module.
VCM_OP_STATE_FW_INCOMPATIBLE_MISMATCH
Possible cause: The firmware running on this module is different than the firmware on the active VC-Enet

module.
Action: Upgrade the firmware to the version running on the active module.

Enclosures View

This graphical representation consists of an enclosure front view and rear view. To display a window with
information about a particular device, mouse over that device in this graphical view.
The Enclosures view provides status on each device in the enclosure and the option to select an individual

device for more detailed information.

Advertising