Table 5 – HP XP Array Manager Software User Manual

Page 30

Advertising
background image

2.

See

Table 5

, page 30 for a description of the error code.

For details about the error codes that are not described in

Table 5

, page 30, contact your HP

Service Representative (see

Calling HP Technical Support

).

Table 5 Error Codes and Error Contents When Using RAID Manager

Description

Error Code (SSB2)

Error Code (SSB1)

The setting failed because the specified volume does not
exist.

B9BD

B9BF/B9BD

The specified volume is a command device.

B9C2

The command was rejected due to one of the following
reasons:

B9C4

•

The specified volume is a P-VOL or S-VOL of XP Snap-
shot

•

The specified volume is a virtual volume.

•

The specified volume is a pool volume.

•

The specified volume is an S-VOL of XP XP Continuous
Access Journal.

•

The specified volume is a journal volume.

•

The specified volume is reserved for the XP Auto LUN
function.

•

The specified volume is a P-VOL or S-VOL of XP XP
Business Copy.

•

The consumed capacity exceeded the licensed capacity.

•

The access attribute cannot be changed because the
data retention term is set.

•

The specified volume is a command device.

•

The specified volume is in the PAIR or COPY status.

•

The specified volume does not exist.

•

The S-VOL Disable attribute is set to the specified
volume.

•

The reserve function cannot be canceled by RAID
Manager.

The Data Retention Utility is not installed.

B9C7

The consumed capacity exceeded the licensed capacity.

B9C9

Either:

B9CA

•

More than 60 years are set as the data retention days,
or

•

The other interface updated the settings while the Data
Retention Utility was changing the settings (Java conflic-
ted with the other interface).

The data retention term cannot be set because the access
attribute is set to Read/Write.

B9CB