Enhanced snmp configuration – HP Virtual Connect Enterprise Manager Software User Manual

Page 26

Advertising
background image

Virtual Connect 2.3x features that must be disabled in a VC Domain to be part of the VC Domain
Group with Virtual Connect firmware 2.1x

IMPORTANT:

If you plan to add Virtual Connect 2.3x to a VC Domain Group with Virtual Connect firmware

2.0, you must disable the Virtual Connect 2.3x features in this section and the Virtual Connect 2.1x features
in the following section.

•

Enhanced SNMP configuration is not supported.

Figure 3-2 Enhanced SNMP configuration

Do not configure the VC Domain using the enhanced SNMP configuration. If necessary, disable the
enhanced SNMP configuration by following these steps:

1.

Do not configure more than five SNMP trap destinations.

2.

Verify that all SNMP trap destinations follow these rules:
a.

The Destination Name must be in the following format:

<IP Address of the SNMP Trap Destination>_<Community String>_<0 for

VC-Enet and 1 for VC-FC>

(for example, 192.168.1.1_public_1)

b.

Select the “ipv4” option.

c.

Set the SNMP trap format to “SNMPv1.”

Figure 3-3 Adding or editing a compatible SNMP trap destination

26

Managing VC Domains