Problem, Suggestion, Cause – HP Intelligent Infrastructure Analyzer Software User Manual

Page 59

Advertising
background image

Remedial measure for the timed out switch :

Reboot your switch and rescan.

Problem

1:
2:
4:
5:
6:
101:
102:
104:
105:

Suggestion

Follow the steps mentioned in

“Correcting conditions with SFPs and FC Cables” (page 57)

.

Problem

3:
103:
203:
303:

Suggestion

Follow the steps mentioned in

“Correcting conditions with SFPs and FC Cables” (page 57)

. If HP

IIAS continues to raise diagnostics logs then the problem may be with the connected SFP. Replace
the connected SFP with another SFP in good condition. If HP IIAS does not raise any diagnostics
log for the SFPs under question, then the problem is addressed successfully.

Problem

IAS Client is not able to connect to IIAS Server. The probable reason
could be that IIAS Server may not be running or has got disconnected.
Please restart the HP IIAS Server and then start the HP IIAS Client again.

Suggestion

Add the environment variable <value of system directory> \wbem to the “PATH”
and restart the command prompt.

Verify if firebird environment variable is used. Also if the same value is appended to ”PATH”
variable. Its value should be <installed directory>\server\lib\Firebird

On XP, after installing HP IIAS, if you get the above specified error, then please restart your
system and try again.

Problem

Even after installing Java, applets do not run.

Cause

Java is not enabled in the web browser. If Java is already installed and the applets do not work,
the you may need to enable Java through your web browser.

Correcting conditions with SFPs and FC cables/connectors

59

Advertising
This manual is related to the following products: