Lsu optics adapter, Actions, Disable pe reintegration – HP Integrity NonStop J-Series User Manual

Page 201: Disable serial zx1 i/o link, Enable pe reintegration, Enable serial zx1 i/o link, Power down lsu, Reintegrate pe

Advertising
background image

The serial number of the component assigned to it by the supplier of the
component.

Serial Number

The ID of the slot in which the LSU logic board resides.

Slot ID

LSU Optics Adapter

NOTE:

These attributes are displayed for NonStop NS14000 series and NS16000 series servers

only.

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Hardware Revision

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Part Number

The serial number of the component assigned to it by the supplier of the
component.

Serial Number

Link Status of the A cable connecting the LSU and the processor element.

Serial ZX1 I/O Link A Status

Link Status of the B cable connecting the LSU and the processor element.

Serial ZX1 I/O Link B Status

Link Status of the C cable connecting the LSU and the processor element.

Serial ZX1 I/O Link C Status

The ID of the slot in which the LSU optics adapter resides.

Slot ID

Actions

These actions are available for NonStop NS14000 series and NS16000 series servers only. For
NonStop NS1000, NS1200, NS2000 series, NS2100, NS2200 series, NS2300, NS2400
series, NS5000, and NS3000AC servers, there are no actions under the Processor Components
object.

Disable PE Reintegration

Disables automatic reintegration of the PE (A or B or C). The automatic reintegration remains
disabled for only 60 minutes after this action is performed.

Disable Serial ZX1 I/O Link

Disables the link (A or B or C) between the LSU and the processor element.

Enable PE Reintegration

Enables automatic reintegration of the PE (A or B or C) after a failure.

Enable Serial ZX1 I/O Link

Enables the link (A or B or C) between the LSU and the processor element.

Power Down LSU

This action effectively disconnects the LSU for this processor from the system and puts the LSU into
low power mode, enabling it to be serviced. The LSU will only remain in low power mode for the
time specified when performing the action; between 3 and 60 minutes. If more service time is
required, remove the LSU optics adapter or logic board from its slot after performing the Power
Down LSU action.

Reintegrate PE

Brings the PE into the same state as currently running Blade Elements.

Processor Components 201

Advertising
This manual is related to the following products: