Fcip with remote iscsi hosts, Figure 57: fcip with remote iscsi hosts, 57 fcip with remote iscsi hosts – HP StorageWorks IP Storage Router User Manual
Page 230
 
Recommended Host/Storage Configurations
230
IP Storage Router SR2122-2 User Guide
FCIP with Remote iSCSI Hosts
The FCIP configuration with local iSCSI hosts may be extended by locating the 
iSCSI hosts apart from either site A or site B. This configuration requires that the 
iSCSI IP network be connect to the large SAN through a WAN network as shown 
in 
Figure 57: FCIP with remote iSCSI hosts
This configuration allows the iSCSI hosts to access disk LUNs at either site A or 
site B, providing maximum configuration flexibility.
Note:
Within the WAN network the iSCSI protocol traffic is kept isolated from the FCIP
protocol traffic and connects to the SR2122-2s through the second Gigabit Ethernet port
on each gateway.
The SR2122-2 has the capability to rate-limit or "pace" the FCIP protocol traffic 
that it handles. This is accomplished using standard Fibre Channel flow control 
mechanisms which allows the user to limit the amount of FCIP traffic through the 
SR2122-2 so that it does not exceed the bandwidth allotted for this connection 
through the WAN network.
However, the iSCSI protocol traffic has no corresponding flow control 
mechanism. If the iSCSI protocol traffic and the FCIP protocol traffic are 
combined on a single network and if the combined traffic exceeds the available 
FC disk A
FC disk B
FC tape A
FC tape B
(iSCSI)
WAN network
(FCIP)
FC network A
FC network B
IP network
(iSCSI)
FC Host A
HP SR2122-2 A
HP SR2122-2 B
FC Host B
iSCSI Host
15061