2.1.7.4 SL2x170z G6 and DL170h G6 Servers BIOS setting
IMPORTANT:
To enable BIOS updates, you must restart the server. You can restart the server
with Ctrl+Alt+Delete immediately after leaving the BIOS, or you can physically restart the server
by using the power switch on the server.
Figure 3 NIC2 on the SL2x170z G6 Server
•
BIOS settings
Post speedup Enabled
◦
◦
Numlock Enabled
◦
Restore after AC loss Last state
◦
Post F1 prompt Delayed
•
CPU setup
Proc hyper threading Disabled
◦
•
IDE configuration
SATA controller mode AHCI
◦
◦
Drive cache Enabled
◦
IDE timeout 35
•
Chipset ACPI configuration
High Performance Event timer Enabled
◦
•
IPMI serial port configuration
Serial port assignment BMC
◦
◦
Serial port switching Enabled
◦
Serial port connection mode Direct
•
LAN configuration
If your node is wired with the LO100i management port shared with NIC2:
◦
BMC NIC Allocation Shared
◦
LAN protocol: HTTP, telnet, ping Enabled