Replacing, moving, or adding hard drives 21

Compromised fault tolerance

CAUTION:

When fault tolerance is compromised, data loss can occur. However, it may be

possible to recover the data. For more information, see "Recovering from compromised fault

tolerance (on page

21

)."

If more drives fail than the fault-tolerance method can manage, fault tolerance is compromised, and the

logical drive fails. If this failure occurs, the operating system rejects all requests and indicates unrecoverable
errors.
For example, fault tolerance may be compromised when a drive in an array fails while another drive in the

array is being rebuilt.
Compromised fault tolerance can also be caused by problems unrelated to drives. In such cases, replacing

the physical drives is not required.

Recovering from compromised fault tolerance

If fault tolerance is compromised, inserting replacement drives does not improve the condition of the logical

volume. Instead, if the screen displays unrecoverable error messages, perform the following procedure to
recover data:

1.

Power down the entire system, and then power it back up. In some cases, a marginal drive will work
again for long enough to enable you to make copies of important files.
If a 1779 POST message is displayed, press the F2 key to re-enable the logical volumes. Remember that
data loss has probably occurred and any data on the logical volume is suspect.

2.

Make copies of important data, if possible.

3.

Replace any failed drives.

4.

After you have replaced the failed drives, fault tolerance may again be compromised. If so, cycle the
power again. If the 1779 POST message is displayed:

a.

Press the F2 key to re-enable the logical drives.

b.

Recreate the partitions.

c.

Restore all data from backup.

To minimize the risk of data loss that is caused by compromised fault tolerance, make frequent backups of all

logical volumes.

Replacing hard drives

If you are replacing a drive in a fault-tolerant configuration while the system is powered down, a POST

message appears when the system is powered up. When this message appears, press the F1 key to enable

automatic data recovery. If you do not enable automatic data recovery, the logical volume remains in a

ready-to-recover condition, and the same POST message appears when the system is restarted.
In RAID 1 configurations, you can replace one failed drive.
In RAID 1+0 configurations, drives are mirrored in pairs. If drives are not mirrored to removed or failed

drives, you can replace them simultaneously.