Migrating drives to an optional host bus adapter – HP Dynamic Smart Array Controllers User Manual
Page 29

Replacing, moving, or adding hard drives 29
7.
Install the access panel.
8.
Reboot the server. At boot, press F5 for ACU or F10 for Intelligent Provisioning.
9.
Select the newly installed card.
10.
Set the preferred logical volume as the boot volume.
11.
Exit ACU or Intelligent Provisioning, and then reboot the server.
The optional Smart Array controller should appear at boot. It should have the same number of logical
volumes that were configured for the Dynamic Smart Array controller.
Migrating drives to an optional host bus adapter
For information on installing an optional host bus adapter and migrating the drives, see the HP Host Bus
Adapters for HP ProLiant Servers Installation Guide on the HP website
Upgrading or migrating from a host bus adapter to a B320i
controller
CAUTION:
Back up all data before moving drives from a B-series controller to a host bus
adapter. Otherwise, data will be lost.
To upgrade or migrate from a host bus adapter to a B320i controller:
1.
Back up all data.
2.
Be sure the latest BIOS is installed. If it is not installed, use Intelligent Provisioning (on page
) to install
the latest BIOS.
3.
If necessary, enable the controller ("
" on page
4.
Configure the array ("
" on page
5.
Install the device drivers ("
" on page
6.
Restore the backed-up data to the drives.