When storage systems or hosts are under a heavy load, migration might fail. In this case, reduce
the load on the storage systems, and then perform data migration again.

If data migration fails, the integrity of data at the migration target cannot be ensured. Therefore,
data migration must be performed again.

If operations on a migration target volume, such as the re-execution of data migration and volume
allocation, cannot be performed after the data migration fails, the storage system must be refreshed.

Values for ensuring the operation of Tiered Storage Manager and recommended
values

The values below ensure the operation of Tiered Storage Manager. Performance might slow down
or memory might become insufficient if a value exceeds these values.

Table 6 Tiered Storage Manager operational values

Recommended value

Value for which performance is ensured

Item

30 or less

100

Number of tiers in a
single storage system

1,000 or less

1,300

Number of unused
volumes a tier

5 or less

maximum of 500

Number of volumes that
can be migrated at once

N/A

maximum of 2,000

Number of volumes that
can be displayed as can-
didates for migration tar-
get volumes

Conditions for data migration

Data migration conditions include conditions that apply to all volumes (volume migration requirements),
and conditions that depend on the type of volume (volume migration requirements related to volume
type).

For some volumes, when you try to select those volumes as migration-source volumes, the reasons
why they cannot be selected as migration-source volumes are displayed on-screen.

Volume migration requirements

All volumes for which data migration is to be performed must meet the following conditions:

Migration-source and migration-target volumes exist within one of the following storage systems
(chassis):
• P9500 Disk Array
• XP24000/XP20000
• XP12000/XP10000/SVS200

The emulation type, number of blocks, and size are the same for the source and target migration
volumes. However, note the following exceptions:
• If the micro version of XP24000/XP20000 is 60-03-20-00/00-xx or later and if both the mi-

gration source and the migration target volumes are THP/Smart volumes, the emulation type
can be between OPEN-V and OPEN-0V.

Setting up and operating a SAN environment

76