Hp technical support, Table 4, Ibed in – HP XP Array Manager Software User Manual

Page 32

Advertising
background image

1.

Find the error code from the logs displayed on the RAID Manager window.

Figure 15

shows an example of a log displayed on the RAID Manager window.

Figure 15 Example of a Log Displayed on the RAID Manager Window

Error codes appear on the right of SSB=. The alphanumeric characters of last four digits on the
left of the comma(,) indicates SSB1 (for example, B9E1), and the alphanumeric characters of
last four digits on the right of the comma (,) indicates SSB2 (for example, B901).

2.

See

Table 4

and find the meaning of the error code. For details about the error codes that are

not described in

Table 4

, contact your HP Service Representative (see

HP Technical Support

).

Table 4 Error Code and Error Contents when Operating RAID Manager

Description

Error Code
(SSB2)

Error Code
(SSB1)

The command was rejected because the setting information for DataBase
Validator was incorrect.

B9B3

B9B0

The command was rejected because the LU being used by Database
Validator is not defined.

B9B4

The command was rejected because Database Validator program product
is not installed.

B9B5

The command was rejected because the microcode which supports
Database Validator and the microcode which does not support Database
Validator exist together.

B9B6

The command was rejected because the LU being used by Database
Validator is a command device.

B9B7

The command was rejected because the LU being checked by Database
Validator is not defined.

B9B4

B9B1

HP Technical Support

For worldwide technical support information, see the HP support website:

http://www.hp.com/support

Before contacting HP, collect the following information:

Product model names and numbers

Technical support registration number (if applicable)

Product serial numbers

Error messages

Operating system type and revision level

Detailed questions

Troubleshooting

32