Description

SSB2 code

The Quick Restore was rejected because of one of the following:

2097

The P-VOL is also an THP V-VOL, but the S-VOL is a normal volume.

The P-VOL is a normal volume, but the S-VOL also an THP V-VOL.

The pair task was rejected because the volume you specified as the P-VOL is a Mainframe Fibre Data
Migration volume.

209E

The create pair task was rejected because the P-VOL is an THP or Smart V-VOL for which the capacity
is increasing.

20A2

The pair was not created because the S-VOL is an THP or Smart V-VOL for which capacity is increasing.

20A3

The pair task was rejected because FS is using the specified CG number.

20A9

The create pair task was rejected because the volume you specified as the P-VOL is an THP or Smart
V-VOL and either its zero pages were being reclaimed or the WriteSame or Unmap command is
being processed.

20AA

The create pair task was rejected because the volume you specified as the S-VOL is an THP or Smart
V-VOL and either its zero pages were being reclaimed or the WriteSame or Unmap command is
being processed.

20AB

The pair task was rejected because the volume you specified as the P-VOL is an THP or Smart V-VOL
and its capacity is increasing.

20B0

The pair task was rejected because the volume you specified as the S-VOL is an THP or Smart V-VOL
and its capacity is increasing.

20B1

The pair task was rejected because the volume you specified as the P-VOL is an THP or Smart V-VOL,
which is not associated with a pool.

20B4

The pair task was rejected because the volume you specified as the S-VOL is an THP or Smart V-VOL,
which is not associated with a pool.

20B5

The command was rejected because you were in the process of turning off the storage system’s power.

20C5

The P-VOL rejected the Paircreate RAID Manager command because the THP pool is initializing
in the THP or Smart V-VOL.

20D0

The S-VOL rejected the Paircreate RAID Manager command because the THP pool is initializing
in the THP or Smart V-VOL.

20D1

The pair task was rejected because the volume you specified as the P-VOL is an external volume that
is mapped for online data migration.

20DE

The volume which was specified as the S-VOL cannot be used, because the volume is undergoing
online data migration.

20DF

The pair task was rejected because the volume you specified as the P-VOL is a S-VOL for an existing
pair, and the volume you specified as the S-VOL is the P-VOL for another existing pair.

20E9

The volume which was specified as the P-VOL cannot be used, because the volume is undergoing
online data migration and Cache Through is specified as the cache mode.

20EC

The pair task was rejected because even though the specified serial number matches the virtual storage
machine, the physical storage system's serial number that corresponds with the virtual storage machine's

20F2

serial number does not match when the virtual storage machine's serial number is specified for P-VOL
and S-VOL.

The pair task was rejected for the volume specified as the P-VOL because either the device model and
serial number or the virtual LDEV ID for the virtual storage machine is being changed.

20F4

The pair task was rejected for the volume specified as the S-VOL because either the device model and
serial number or the virtual LDEV ID for the virtual storage machine is being changed.