HP XP Racks User Manual

Page 80

Advertising
background image

Description

SSB2 code

The pair was not created because the volume you specified as the S-VOL is the S-VOL of another pair
that has been split (“PSUS” status).

2314

The pair was not restored because the P-VOL of the specified pair is online to the host.

231F

The pair task was rejected because there is not a sufficient amount of installed shared memory or
initialization is not completed.

2322

The pair task was rejected because the number of slots of the volume you specified as the P-VOL
exceeded the upper limit.

2324

The pair task was rejected because the number of slots of the volume you specified as the S-VOL
exceeded the upper limit.

2325

The pair was not created because the volume you specified as the P-VOL had already had three
S-VOLs.

2326

The pair was not created because the node volume specified as the P-VOL had already had two
S-VOLs.

2327

The pair task was rejected because the pair configuration exceeded the number of the layers of the
cascade configuration.

2328

The pair task was rejected because the volume you specified as the S-VOL is the S-VOL of an existing
pair.

2329

The pair was not created because pairs that would exceed the license capacity were going to be
created.

232A

The pair task was rejected because the volume you specified as the P-VOL is allocated as the destination
of the Auto LUN.

232F

The pair task was rejected because the capacity of the specified P-VOL is not the same as the S-VOL’s.

2331

The pair was not created because the volume you specified as the P-VOL had already had three
S-VOLs.

2332

The pair task was rejected because the volume you specified as the P-VOL is not the P-VOL of the
existing pair.

2333

One of the following occurred:

The CG pair-split was rejected because the volume you specified as the P-VOL is an intermediate
volume.

2334

The pair task was rejected because the volume you specified as the S-VOL had an emulation type that
could not be handled by RAID Manager.

2335

The pairresync RAID Manager command was rejected because the volume you specified as the
P-VOL is not a BC P-VOL.

233A

The pair task was rejected because the volume you specified as the S-VOL is a root volume.

233B

The pair task was rejected because the volume you specified as the S-VOL is a node volume, and the
volume you specified as the P-VOL is not the P-VOL for the specified S-VOL.

233C

The pairsplit RAID Manager command was rejected because the specified P-VOL and S-VOLs
were a L2 pair, and the L1 pair is not split (“PSUS” status).

233D

The pair task was rejected because the volume you specified as the P-VOL is being used as the Cnt
Ac-S P-VOL.

233E

The pair task was rejected because the volume you specified as the S-VOL is the Cnt Ac-S P-VOL, and
the pair is not split (“PSUS” status) or suspended (“PSUE” status).

233F

The pair task was rejected because the volume you specified as the S-VOL is the destination of the
Auto LUN.

2342

The pair was not created because the volume you specified as the S-VOL had already been an S-VOL.

2343

80

Troubleshooting Business Copy

Advertising
This manual is related to the following products: