HP IO Accelerator for BladeSystem c-Class User Manual

Page 49

Advertising
background image

Utilities 49

Data Volume Information: If the -d option is used, then the following data volume information is reported in

addition to the basic information:

•

Physical bytes written

•

Physical bytes read

All Information: If the -a option is used, then all information is printed, which includes the following

information in addition to basic and data volume information:
Adapter information:

•

Manufacturer number

•

Date of manufacture

•

Power loss protection status

•

PCIe bus voltage (avg, min, max)

•

PCIe bus current (avg, max)

•

PCIe power limit threshold (watts)

•

PCIe slot available power (watts)

•

PCIe negotiated link information (lanes and throughput)

Block device information:

•

Part number

•

Manufacturer's code

•

Manufacturing date

•

Vendor and sub-vendor information

•

Size of the device, out of total capacity

•

Format status and sector information (if device is attached)

•

FPGA ID and Low-level format GUID

•

PCIe slot available power

•

PCIe negotiated link information

•

Card temperature, in degrees Centigrade

•

Internal voltage: avg. and max.

•

Auxiliary voltage: avg. and max.

•

Percentage of good blocks, data and metadata

•

Lifetime data volume statistics

Error Mode Information: If the IO Accelerator is in minimal mode, read-only mode, or write-reduced mode
when fio-status is run, the following differences occur in the output:

•

Attach status is Status unknown: Driver is in MINIMAL MODE:

•

The reason for the minimal mode state is displayed (such as Firmware is out of date. Update

firmware.)

•

Geometry and capacity information not available. appears.

•

No media health information appears.

Advertising
This manual is related to the following products: