HP StorageWorks XP Remote Web Console Software User Manual

Page 89

Advertising
background image

TrueCopy for z/OS user guide

89

required for the initial copy operation is large, it means that the workload of the update copy is relatively

high. Therefore, the copy pace of the initial copy will be slowed. When the time is relatively small, the

copy pace will speed up to the specified value. In this way, we can curb the influence of the exclusive line

use in the initial copy operation on the host performance.

NOTE:

This option is available only in the case of TCz pairs (In the case of TCzA pairs, this option value

is invalid).

The default value of Round Trip Time is 1 ms. You may specify 1 ms to 500 ms. You can use the following

formula to figure out the Round Trip Time.

For Round Trip Time between MCU and RCU, please ask your carrier, or use a ping command and etc. to

measure the time. If you do not use lines etc. between MCU and RCU, specify “1.”
Initial Copy response time is the response time required for multiple initial copy operations. You can use

the following formula to get the Initial Copy response time. To get the time, you should use the following

values: the initial copy pace, the max number of initial copy VOLs, the speed of the line between MCU

and RCU, and the number of lines.

Round Trip time = Round Trip Time between MCU-RCU x 2

1

+ Initial Copy response time (ms)

1. A data transfer between MCU and RCU involves two response sequences in one command issuance. Therefore, you need to

double the Round Trip Time between MCU-RCU.

Initial Copy response time (ms) = (1[MB]/“Speed of line between MCU-RCU[MB/ms]”

1

)

x (“initial copy pace”

2

/15)

x (“max number of initial copy VOLs”

3

/“Number of

lines between MCU-RCU”

4

)

1. When you connect MCU with RCU without lines etc., specify 0.17[MB/ms] in “Speed of line between MCU and RCU.”
2. For “initial copy pace” in the formula above, see

Table 18

.

3. For the maximum number of initial copy volumes, see ”

Initial Copy Operations

” on page 27. The default is 64.

4. Even if “Max number of initial copy VOLs”/“Number of lines between MCU-RCU” is larger than 16, specify “Max number of

initial copy VOLs”/“Number of lines between MCU-RCU” as 16.

Table 18

Initial Copy Pace for Calculating The Initial Copy Response Time

Perform Initial

Copy Only

Perform Initial Copy and Update Copy

at a Time
Initial Copy Pace

Specified at the

Time of Pair

Creation is 1 to 8

Initial Copy Pace

Specified at the

Time of Pair

Creation is 9 to 15

Operation

Storage Navigator

Initial copy pace

specified at the time

of pair creation

Initial copy pace

specified at the time

of pair creation

8

Business Continuity

Manager

Initial copy pace

specified at the time

of pair creation

Initial copy pace

specified at the time

of pair creation

8

PPRC command

(TSO/ICKDSF) and

CU emulation

type=3390

Initial copy pace

specified at the time

of pair creation

Initial copy pace

specified at the time

of pair creation

8

PPRC command

(TSO/ICKDSF) and

CU emulation

type=2150

15

1

8

1

Advertising