Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in

the controller firmware and the operating system driver.

Unknown—Indicates that the Storage Agents cannot determine the redundancy type for the controller. You

may need to upgrade the Storage Agents.

Redundancy Error—Displays the redundancy error for the controller. The following values are valid:

No Failure—No failures have been detected.

No Redundant Controller—No redundant controller is installed.

Different Hardware—The other controller indicates a different hardware model.

No Link—A link to the other controller could not be established.

Different Firmware—The other controller indicates a different firmware version.

Different Cache—The other controller indicates a different cache size.

Other Cache Failure—The other controller indicates a cache failure.

No Drives—This controller cannot see any attached drives, but the other controller can.

Other No Drives—This controller can see the attached drives, but the other controller cannot.

Unsupported Drives—One or more attached drives has been determined to be incapable of properly

supporting redundant controller operation.

Expand in Progress—An expand operation is in progress. Redundant operation not supported until the

expand operation is complete.

Unknown—Indicates that the Storage Agents are unable to determine the redundancy error for the

controller. You may need to upgrade the Storage Agents.

Firmware Version—L

ists the firmware version of the array controller. This value can be used to help

identify a particular revision of the controller.

Product Revision—Displays the revision of the array controller board. This value can be used to help identify a

particular revision of the controller.

Serial Number—Displays the serial number for the array controller. Use this number for identification purposes.

Processor Usage—Displays the total percentage of the processor usage, expressed as a number from 0 to 100

inclusive.

Command Count—Displays the total number of read and write commands processed in this sample. This value

is expressed as read and write commands per second.

Command Latency—Displays the average command latency for this sample in 1/100,000 of a second units.

ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The module enables

advanced controller features such as Advanced Data Guarding. The following values are valid:

Not Supported—Indicates that the RAID ADG Enabler Module is not supported by this type of controller.

Not Present—Indicates that the RAID ADG Enabler Module is not present or is not accessible.

Fully Functional—Indicates that the RAID ADG Enabler Module is functional and accessible.

Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.

Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.

Present - Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed, but a firmware

upgrade is required to make it fully functional.

Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler Module. You may

need to upgrade the Storage Agents.

Daughter Board Type—D

isplays the type of daughter board installed on the array controller. The

following values are valid:

Not Supported—Indicates that the array controller does not support daughter boards or it does not support

daughter board identification.

Not Present—Indicates that a daughter board is not installed on the array controller.

SCSI—Indicates that a SCSI daughter board is installed on the array controller.

Fibre—Indicates that a Fibre daughter board is installed on the array controller.

Array—Indicates that an Array Expansion Module is installed on the array controller.

Unknown—Indicates that the daughter board type is not recognized. You may need to upgrade the Storage

Agents.

Rebuild Priority—D

isplays the logical drive rebuild priority of the controller. The following values are

valid:

Low—Indicates the rebuild priority is low.

Medium—Indicates the rebuild priority is medium.