Drive information, Raid arrays, Mass storage controller – HP ProLiant DL380 G5 Server User Manual

Page 85: Clustered raid controller, Mass storage summary, Cr3500 shared storage system, Environment monitoring unit

Advertising
background image

Formatting—The drive is currently being formatted.

Action—Provides a brief description of an action you can take depending on the physical drive condition

Drive information

Capacity—Displays the total capacity of the selected drive in megabytes

Firmware Version—Displays the firmware revision of the selected drive

Drive Owner—Lists a descriptive name for the drive owner

Model—Displays the model number of the selected drive

Vendor—Displays the vendor of the selected drive

RAID Arrays

RAID Arrays—Lists the RAID arrays by channel number and SCSI ID

Mass Storage controller

This section displays Array Controller information.

Clustered RAID controller

Controller Status—Displays the current controller status. The following conditions are valid:

OK—All controller functions are operating normally.

Degraded—The controller is operating in a degraded or reduced state.

Failed—The controller is inoperable.

Current Role—Displays if the controller is in simplex or duplex role.

Firmware Version—Displays the current software revision.

Serial Number—Displays the controller serial number.

Drive Ownership—Lists a descriptive name for the drive owner.

Rebuild Rate—Displays the rebuild rate. The rebuild rate ranges from 1 to 100. The controller rebuilds while at

the same time it handles I/O activity. A rate below 50 emphasizes I/O response over the RAID rebuild. A rate

above 50 puts a higher priority on the RAID rebuild at the expense of I/O activity.

Create Rate—Displays the create rate. The create rate ranges from 1 to 100. The controller creates RAID sets

while, at the same time, handles I/O activity. A rate below 50 emphasizes I/O response over the RAID set

creation. A rate above 50 puts a higher priority on the RAID set creation at the expense of I/O activity.

Cache Size—Displays the cache size in megabytes.

DIMM A Size—Displays the Dual Inline Memory Module A size in megabytes.

DIMM B Size—Displays the Dual Inline Memory Module B size in megabytes .

Mass Storage Summary

CR3500 Shared Storage system

This section displays degraded or failed devices in the CR3500 Shared Storage system.
The following is a list of devices in CR3500 Shared Storage system:

Clustered RAID Controller

RAID Array

Physical Drive

Spare Drive

Environment Monitoring Unit

Environment Monitoring Unit

This section displays the Environment Monitoring Unit information.

Primary enclosure temperature status—Displays the current primary enclosure temperature status. The following

conditions are valid:

OK—The primary enclosure temperature is within normal parameters.

CR3500 RAID Array SCSI controller 85


Advertising
This manual is related to the following products: