HP NonStop G-Series User Manual

Page 59

Advertising
background image

Troubleshooting

M8501 and M8502 ACL Tape Drive Installation and User’s Guide 529972-003

6 -5

Fault Symptom Codes (FSCs)

Open Doors Fault

2093

C, G

Door open sensor time-out detected when
open door.

Open DLT Handle
Fault

2094

C, G

Failed to open DLT handle.

No IP Address Found

20a0

C, G

SMC router failed to get an IP address.

No IP Address Mode
Fault

20a1

C, G

SMC router failed to detected static or ip
address Mode.

Unknown exchange
for the async
message

20b0

C, G

Unexpected exchange detected when
process Messages.

Drive In Error

20c0

C, G

Control failed to set SCSI id.

Drive In Error

20c1

C, G

Control failed to installed drive.

Drive In Error

20c0

C, G

Control failed to set SCSI id.

Drive In Error

20c1

C, G

Control failed to installed drive.

Motor Fault Condition

3000

C, G

One of the motors has been disabled and
could not be re-enabled.

Picker Tach Errors

3002

C, G

Picker Tach errors were detected when
checking slots.

Bin Fetch Failure

3001

C, G

Loader failed to fetch a cartridge from a
bin.

Drive Fetch Failure

3013

C, G

Loader failed to fetch a cartridge from the
drive.

Drive Time-out Failure

3015

C, D, G

Loader detects unload command time-
out.

Drive Status Failure

3016

C, D, G

Detected drive error from fetch, stow and
wait for handle ok DLT drive operation.

Drive In Flux Time-out

3017

C, D, G

Time-out waiting for drive to clear the flux
status.

Drive Load Retry
Failed

3018

C, G

LTO drive fail to load, detected in drive
task.

Drive OpenDoor
Failed

3019

C, G

Failed open DLT door.

Drive Close Door
Failed

301A

C, G

Failed close DLT drive door.

Drive Communication
Error

301B

C, D, G

Intertask send, receive failed.

Drive Get General
Status Fail

301C

C, D, G

Drive communication failed.

Drive Get Status 3 Fail

301D

C, D, G

NOT USED

Table 6-2. Fault Symptom Codes