Summary: fibre channel host configuration, Configure the iscsi host, Introduction to configuring the iscsi host – HP 3PAR Operating System Software User Manual

Page 21: Connect to the iscsi host system, Configure multipath i/o (mpio)

Advertising
background image

Summary: Fibre Channel Host Configuration

1.

Review your Fibre Channel setup.

2.

Click Finish.

If you are connected to the local host and rebooted the host system, the local host reboots.

After the local host has finished rebooting, launch SmartStart and continue setup.

If you are connected to the remote host and rebooted the host system, the remote host
reboots. After the remote host reboots, continue setup.

Configure the iSCSI Host

Introduction to Configuring the iSCSI Host

To set up iSCSI connections, ensure that you have the information necessary to set up the iSCSI
connections between the host system and HP 3PAR StoreServ 7000 Storage system:

Host system IP address or name

iSCSI port information

MTU (maximum transmission unit) size:

If you are using default frames, use an MTU of 1500.

If you have configured jumbo frames, use an MTU of 9000.

Configuring Local and Remote Connections

You can use SmartStart to:

Connect the local host (the Windows 2008 R2 server into which you inserted the SmartStart
media) to the HP 3PAR StoreServ Storage system

Connect a remote host (any Windows 2008 R2 server other than the Windows 2008 R2
server into which you inserted the SmartStart media) to the HP 3PAR storage system

To connect to and configure a remote host system:

You must be able to use the same ID and password to gain administrator access to both
the local host and the remote host. If you cannot use the same login, you must insert the
SmartStart media into the remote host and configure the machine as a local host.

If you have set up domains on your local host system and plan to configure a remote host
system, that remote host must be in the same domain as the local host.

Connect to the iSCSI Host System

1.

In the Host address text box:

If you are configuring the machine into which you inserted the SmartStart media, enter:
localhost

If you are configuring any host other than the machine running SmartStart, enter that host
IP address or DNS

2.

Click Connect.

3.

Click Next.

Configure Multipath I/O (MPIO)

Multipath I/O helps ensure the stability of the connection between the host and HP 3PAR StoreServ
Storage systems.

Configure the iSCSI Host

21

Advertising
This manual is related to the following products: