Pci riser cage led – HP ProLiant DL380 G5 Server User Manual

Page 18

Advertising
background image

Component identification 18

Online/activity
LED (green)

Fault/UID LED
(amber/blue)

Interpretation

Flashing

irregularly

Amber, flashing

regularly (1 Hz)

The drive is active, but a predictive failure alert has been

received for this drive. Replace the drive as soon as possible.

Flashing
irregularly

Off

The drive is active, and it is operating normally.

Off

Steadily amber

A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as

possible.

Off Amber,

flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

Off

Off

The drive is offline, a spare, or not configured as part of an
array.

PCI riser cage LED

CAUTION:

To prevent damage to the server or expansion boards, power down the server and

remove all AC power cords before removing or installing the PCI riser cage.

Status

On = AC power connected
Off = AC power disconnected