Install the access panel, Remove the pci riser cage – HP ProLiant DL380 G5 Server User Manual

Page 25

Advertising
background image

Operations 25

To remove the component:

1.

Power down the server if performing a non-hot-plug installation or maintenance procedure ("

Power

down the server

" on page

23

).

2.

Extend the server from the rack (on page

23

).

3.

Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security screw on the
hood latch.

4.

Lift up on the hood latch handle and remove the access panel.

Install the access panel

1.

Place the access panel on top of the server with the hood latch open. Allow the panel to extend past
the rear of the server approximately 1.25 cm (0.5 in).

2.

Push down on the hood latch. The access panel slides to a closed position.

3.

Use the T-15 Torx screwdriver attached to the rear of the server to tighten the security screw on the
hood latch.

Remove the PCI riser cage

CAUTION:

To prevent damage to the server or expansion boards, power down the server and

remove all AC power cords before removing or installing the PCI riser cage.

1.

Power down the server (on page

23

).

2.

Extend the server from the rack (on page

23

).

3.

Remove the access panel (on page

24

).

4.

Disconnect any internal or external cables connected to any existing expansion boards.

5.

Press the blue button to release the black knob.

6.

Turn the black knob counter-clockwise.

7.

Remove the PCI riser cage.

Advertising