HP ProLiant DL360e Gen8 Server User Manual
Page 39

Hardware options installation 39
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel (on page
5.
Remove the PCI riser cage (on page
CAUTION:
When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.
6.
Connect the capacitor pack cable to the cache module.
7.
If using the embedded array controller:
a.
Install the cache module on the system board.
b.
Install the PCI riser cage (on page
8.
If using an integrated array controller: