Deleting host groups, Initializing the host group 0 (zero), Changing wwns, iscsi names, and nicknames – HP StorageWorks XP Remote Web Console Software User Manual

Page 35

Advertising
background image

LUN Configuration and Security Manager XP user guide for the XP1024/XP128

35

3.

To change the host mode, select the new host mode from the Host Mode list.

4.

If necessary, select Option, and select the host mode options. For detailed information about host

mode options, see

Table 10

on page 31.

5.

Click OK. The settings are shown in blue in the LU Path table.

6.

Click Apply in the LUN Manager main pane. A confirmation message appears.

7.

Click OK. The settings are applied to the disk array.

Deleting host groups

You cannot delete the host group 0 (zero). If you want to remove all the WWNs and LU paths from the

host group 0, you must initialize the host group 0 (”

Initializing the host group 0 (zero)

” on page 35).

1.

In the LU Path tree on the LUN Manager main pane, right-click a host group and select Delete Host

Group. A confirmation message appears.

2.

Click Yes to delete the host group. The host group you specified is removed from the LU Path tree.

3.

Click Apply in the LUN Manager main pane. A confirmation message appears.

4.

Click OK. The settings are applied to the disk array.

Initializing the host group 0 (zero)

Initializing the host group 0 sets the group to its default state. This process:

Removes all the WWNs from the host group 0 and all the LU paths related to the host group 0.

Changes the host mode of the host group 0 to Standard and initializes the host group name. For

example, if you initialize the host group 0 for the port CL1-A, the name of the host group 0 will change

to 1A-G00.

1.

In the LU Path tree on the LUN Manager main pane, right-click the host group 0 and select Clear Host

Group. A confirmation message appears.

2.

Click Yes.
• The host mode and host group name are changed in the LU Path tree.
• WWNs are removed from host group 0.
• LU paths are removed from the LU Path table.
• The LUNs corresponding to the removed LU paths are shown in blue.

3.

Click Apply in the LUN Manager main pane. A confirmation message appears.

4.

Click OK. The settings are applied to the disk array.

Changing WWNs, iSCSI names, and nicknames

1.

In the LU Path tree, locate the port the HBA is connected to and verify that LUN security is enabled.

NOTE:

If the port icon has a key ( ), LUN security is enabled.

If LUN security is not enabled, right-click the port and select LUN Security: OFF->ON in the shortcut

menu.

Advertising
This manual is related to the following products: