HP Traffic Director Server Appliances User Guide

54

save

Saves the current configuration. Changes made during the current
Boot Monitor session are lost unless you use the

save

command.

Example:

monitor>

save

List of currently saved configuration file(s).

You may save over an existing configuration file

or enter a new name.

File name

-------------

active.cfg

bckup.cfg

cris.cfg

‘active.cfg’ is the last booted configuration.

Enter configuration file name (- to cancel):

[active.cfg] --->-monitor>

settime

Selects a method for setting the SA8220’s system time and date. If
you select NTP, you will be prompted for the IP address of the NTP
server(s) you want to use. If you set the date manually, you will be
prompted first for the timezone, then for the date in 24-hour format.

Example, with NTP:

monitor>

settime

Use NTP? [enable] --->

Enter IP address of NTP server or <return> to

end: --->

209.218.240.1

Enter IP address of NTP server or <return> to

end: --->

209.218.240.238

Enter IP address of NTP server or <return> to

end: --->

Example 1, without NTP (manual setting):

NOTE: Example 1 is for
setting the time using
Greenwich Mean Time
(GMT). For example, the
GMT-14 timezone is
GMT minus 14 hours.

monitor>

settime

Use NTP? [disable] --->

Select TIMEZONEs to list (GMT, US, Other or q to

quit: [GMT] --->GMT