Logging out of the cli, Common management operations, Configuring mac cache failover settings – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 50

Advertising
background image

Configuring the Virtual Connect domain using the CLI 50

IGMP allows VC-Enet modules to monitor (snoop) the IP multicast membership activities and to configure

hardware Layer 2 switching behavior of multicast traffic to optimize network resource usage. Currently
only IGMP v1 and v2 (RFC2236) are supported.
The IGMP Snooping idle timeout interval is set to 260 seconds by default. This value is basically the

"Group Membership Interval" value as specified by IGMP v2 specification (RFC2236). For optimum

network resource usage, set the interval to match the configuration on the customer network's multicast
router settings.

Configuring MAC cache failover settings

To configure MAC Cache Failover Settings, use the

set mac-cache

command:

>set mac-cache enabled=true refresh=10

To dispaly MAC Cache Failover Settings, use the

show mac-cache

command:

>show mac-cache

When a VC-Enet uplink that was previously in standby mode becomes active, it can take several minutes

for external Ethernet switches to recognize that the c-Class server blades can now be reached on this

newly-active connection. Enabling Fast MAC Cache Failover causes Virtual Connect to transmit Ethernet
packets on newly-active links, which enables the external Ethernet switches to identify the new connection

(and update their MAC caches appropriately.) This transmission sequence repeats a few times at the

MAC refresh interval (5 seconds recommended) and completes in about 1 minute.

IMPORTANT:

Be sure to set switches to allow MAC addresses to move from one port to

another without waiting for an expiration period or causing a lock out.

Logging out of the CLI

To log out of the CLI, use the

exit

command:

>exit

Common management operations

The following table provides the syntax for the most commonly used management operations.
For detailed information on a particular command, see "Managed elements (on page

9

)."

Operation Examples

Display general domain settings

>show domain

Display predefined address pools

>show domain addresspool

Display interconnect modules

Summary display

>show interconnect

Detailed display

>show interconnect *

Single module display

>show interconnect enc0:2

>show interconnect 4

Display overall domain status

>show status

Advertising