HP EVA P6000 Storage User Manual
Page 107

3.
For iSNS discovery:
a.
Select Initiator and then enter the iSNS name or IP address in the iSNS Address field
(
).
Figure 46 iSNS discovery and verification
b.
Test the connection from the initiator to the iSNS server by selecting Verify iSNS. If
successful, select Save.
If necessary, working on the iSNS server, make the appropriate edits to add the Xtend
SAN iSCSI Initiator to any iSNS discovery domains that include iSCSI module targets.
c.
Select Discover Targets.
d.
Select Discover by iSNS.
A list of module targets appears under Discovered Targets (
).
NOTE:
The module's port may present several iSCSI targets to the Xtend SAN iSCSI
Initiator. Select only one target from the list.
e.
Select the newly-added target under Host name in the left frame.
f.
Check the Visible box (
). This allows the initiator to display the target
status.
g.
Check the Auto Login box. This configures the iSCSI Initiator to automatically log in to
the iSCSI target at system startup.
h.
Click Save.
Figure 47 Selecting newly added target
Set up the iSCSI Initiator 107