HP StorageWorks XP Remote Web Console Software User Manual

Page 43

Advertising
background image

LUN Configuration and Security Manager XP user guide for the XP128/XP1024

43

Copying paths from a Fibre Channel or iSCSI port to a NAS port

CAUTION:

Before performing the following steps, see

Restrictions on port operations

” on page 56 for

important information.

1.

Specify the LU paths to copy:
a. In the LU Path tree, double-click a Fibre Channel or iSCSI port (the copy source port) and then select

a host group. The LU Path table displays LU path information.

b. In the table, select one or more LUNs to which volumes are assigned.

NOTE:

If a volume is assigned to a LUN, the columns on the right of the LUN column are not

empty.

c. Right-click the selected LUNs and select Copy Paths. The selected LUNs turn green.

2.

Paste the LU paths:
a. In the LU Path tree, double-click a NAS port (the copy destination port) to display the User host

group.

b. Right-click the User host group and select Paste Paths.

3.

Click Apply in the LUN Manager tab. A confirmation message appears.

4.

Click OK. The settings are applied to the disk array.

Copying paths from a NAS port to a Fibre Channel or iSCSI port

CAUTION:

Before performing the following steps, see

Restrictions on port operations

” on page 56 for

important information.

1.

Specify the LU paths to copy:
a. In the LU Path tree, double-click a NAS port (the copy source port) and select the User host group.
b. In the LU Path table, select one or more LUNs to which volumes are assigned.

NOTE:

If a volume is assigned to a LUN, the columns on the right of the LUN column are not

empty.

c. Right-click the selected LUNs and select Copy Paths. The selected LUNs turn green.

2.

In the LU Path tree, locate the Fibre Channel or iSCSI port that you want to use as the copy destination

and verify that LUN security is enabled on the port.

NOTE:

If the port icon has a key ( ), LUN security is enabled.

If LUN security is not enabled, right-click the port and select LUN Security: OFF->ON in the shortcut

menu.

3.

Paste the LU paths:
a. Double-click the Fibre Channel or iSCSI port (the copy destination port) to display host groups

below the port.

b. Right-click the host group to which you want to paste paths and select Paste Paths.

4.

Click Apply in the LUN Manager tab. A confirmation message appears.

5.

Click OK. The settings are applied to the disk array.

Advertising