HP XP Auto LUN Software User Manual

Page 46

Advertising
background image

46

Auto LUN XP for the XP12000/XP10000

When you try Auto LUN XP migrations or migration cancellations using RAID Manager, EX_CMDRJE

might appear and the command might be refused, depending on the condition in the disk controller.

Table 13

shows error codes, causes, and solutions for this case.

Table 13

Errors during Auto LUN XP migrations or migration cancellations using RAID Manager

Error code

Cause

Solution

2051

Migration target volume is being used with LUN

Security XP Extension.

Release the volume from LUN Security XP

Extension, and perform the volume migration.

2055

Migration target volume is being used with

Continuous Access XP Journal.

Release the volume from Continuous Access XP

Journal, and perform the volume migration.

2056

Migration source volume is being used with

Continuous Access XP Journal.

Release the volume from Continuous Access XP

Journal, and perform the volume migration.

2057

VMA setting is different between the migration

target and source volumes.

Volume migration cannot be executed. Check the

configuration definition file.

2058

Migration target and source volumes belong to

the same parity group.

Volume migration cannot be executed. Check the

configuration definition file.

2301

Auto LUN XP is not installed on the

XP12000/XP10000.

Install Auto LUN XP, and perform the volume

migration.

2306

LBA size does not match between the migration

target and source volumes.

Volume migration cannot be executed. Check the

configuration definition file.

2309

Maximum number of pairs that can be set in the

disk array is exceeded.

Reduce the number of pairs set in the disk array,

and perform the volume migration (see

Calculating the number of Auto LUN XP

concurrent migration plans”

).

2311

Auto LUN XP already reserved the migration

target volume.

Cancel the Auto LUN XP reservation, and perform

the volume migration.

2312

Migration source volume is online with the host.

Take the migration source volume off-line from the

host, and perform the volume migration.

232F

Migration source volume is already specified as

an Auto LUN XP target volume.

Release the volume from Auto LUN XP, and

perform the volume migration.

2331

Consider the following causes:

Auto LUN XP already reserved the migration

source volume.

Number of slots in the migration target and

source volumes does not match.

Do the following:

1.

Cancel the Auto LUN XP reservation, and

perform the volume migration.

2.

Volume migration cannot be executed. Check

the configuration definition file.

2332

You cannot add pair settings any more to the

migration source volume.

Reduce the number of pair settings of the

specified volume, and perform the migration (see

Calculating the number of Auto LUN XP

concurrent migration plans”

).

2333

Volume specified by the migration cancellation is

not a migration source volume.

RAID Manager is trying to perform the migration

cancellation for a pair that is not migrating.

Check the configuration definition file.

2336

Emulation type of the migration target and source

volumes does not match.

Volume migration cannot be executed. Check the

configuration definition file.

2337

Migration source volume is a Business Copy XP

leaf volume.

Release the Business Copy XP pair, and perform

the volume migration.

233B

Migration target volume is a Business Copy XP

primary volume.

Release the Business Copy XP pair, and perform

the volume migration.

233C

Migration target volume is a Business Copy XP

secondary volume.

Release the Business Copy XP pair, and perform

the volume migration.

Advertising