Hot swapping the 172 mm fans, Removing the 172 mm fans – HP Integrity rx4610 Server User Manual
Page 25

Chapter 3: Installing Fans and Power Supplies
18
Hot Swapping the 172 mm Fans
The four 172 mm cooling fans are mounted in pairs on each side of the chassis. You can hot-swap
these fans without turning the server system power off. Each fan uses an amber LED located on the
fan’s casing to indicate the fan has failed. If it is a failed fan, the amber LED will be illuminated on
the front panel, and the amber LED on the failed fan itself will be illuminated. The individual fan
LEDs may be seen through view-ports in the fan covers
Removing the 172 mm Fans
To remove the 172 mm fan, complete the following steps:
1. Observe all standard safety and ESD precautions.
2. Slide the server out of the rack far enough to expose the fan-access doors near the front sides
of the chassis.
CAUTION
Do not leave the door open for an extended time. Cooling of the system could be
reduced.
3. Slide the plastic latch on the fan cover upwards and pull the door open.
4. Grasp the fan assembly with the finger holes and pull it out.
LED Indicator
Figure 3-1. Removing the 172 mm Fans