Hot swap controller (hsc) – HP Integrity rx4610 Server User Manual

Page 73

Advertising
background image

Chapter 8: Server Management

66

•

Processor

presence

monitoring

•

Speaker ‘Beep’ capability on standby and when system is powered up

•

Itanium processor SEEPROM interface

•

Processor

temperature

monitoring

•

Hot plug PCI slot status monitoring

•

Processor bus speed setting

•

Chassis fan failure light control

•

Chassis power fault light control

•

Chassis power light control

•

SDR/SEL timestamp clock

•

Boardset FRU information interface

•

Fault Resilient Booting (FRB)

•

System management watchdog timer

•

Front panel diagnostic interrupt handling (also called the Init Switch)

•

Diagnostics interrupt (Init status monitor)

•

Event

receiver

•

System interface to the IPMB

•

Secure mode control, including video blank option monitoring and control and front panel

lock/unlock initiation.

•

IPMI Management Controller Initialization Agent

•

Magic Packet and Wake on LAN / Power on LAN support

•

Emergency Management Port (EMP) interface

Intelligent Chassis Management Bus (ICMB) Controller

The ICMB Controller resides on the Legacy I/O Board. It serves as a bridge between the
internal Intelligent Platform Management Bus (IPMB) and the external Intelligent Chassis
Management Bus (ICMB). The internal IPMB transports server management information
within a system, and the external ICMB transports server management information between
various chassis in a server(s) and peripherals cluster configuration.

Hot Swap Controller (HSC)

The Hot Swap Controller (HSC) resides on the Power Distribution Board (T-Docking). The primary
functions of the HSC are as follows:

•

Implements the SAF-TE command set

•

Controls the fault lights