Hot swap controller (hsc) – HP Integrity rx4610 Server User Manual

Page 73

Advertising
background image

Chapter 8: Server Management

66

Processor

presence

monitoring

Speaker ‘Beep’ capability on standby and when system is powered up

Itanium processor SEEPROM interface

Processor

temperature

monitoring

Hot plug PCI slot status monitoring

Processor bus speed setting

Chassis fan failure light control

Chassis power fault light control

Chassis power light control

SDR/SEL timestamp clock

Boardset FRU information interface

Fault Resilient Booting (FRB)

System management watchdog timer

Front panel diagnostic interrupt handling (also called the Init Switch)

Diagnostics interrupt (Init status monitor)

Event

receiver

System interface to the IPMB

Secure mode control, including video blank option monitoring and control and front panel

lock/unlock initiation.

IPMI Management Controller Initialization Agent

Magic Packet and Wake on LAN / Power on LAN support

Emergency Management Port (EMP) interface

Intelligent Chassis Management Bus (ICMB) Controller

The ICMB Controller resides on the Legacy I/O Board. It serves as a bridge between the
internal Intelligent Platform Management Bus (IPMB) and the external Intelligent Chassis
Management Bus (ICMB). The internal IPMB transports server management information
within a system, and the external ICMB transports server management information between
various chassis in a server(s) and peripherals cluster configuration.

Hot Swap Controller (HSC)

The Hot Swap Controller (HSC) resides on the Power Distribution Board (T-Docking). The primary
functions of the HSC are as follows:

Implements the SAF-TE command set

Controls the fault lights

Advertising