Special facilities for windows systems, Signature changing facility for windows systems – HP XP P9500 Storage User Manual

Page 188

Advertising
background image

The raidscan-find sync command flushes the system buffer through finding a logical drive
corresponding to a group of the configuration file, without using the -x mount and -x umount
commands. The following examples are for group ORB.

S-VOL Side

P-VOL Side

Close all logical drives on the P-VOL by application.

Back up the S-VOL data.

Flush the system buffer for P-VOL using raidscan -pi
$LETALL -find sync -g ORB.

Flush the system buffer for S-VOL updates using raidscan
-pi $LETALL -find sync -g ORB when the backup is finished.

Split the paired volume using pairsplit -g ORB with
r/w mode.

Open all logical drives on the P-VOL by application.

Resynchronize the paired volume using pairresync
-g ORB.

Online backup using raidscan-find sync for Windows NT file system:

The raidscan-find sync command flushes the system buffer through finding a logical drive
corresponding to a group of the configuration file, without using the -x mount and -x umount
commands. The following examples are for group ORB.

S-VOL Side

P-VOL Side

Freeze DB on opening P-VOL by application.

Back up the S-VOL data.

Flush the system buffer for P-VOL using the
raidscan -pi $LETALL -find sync -g ORB.

Flush the system buffer for S-VOL updates using raidscan -pi
$LETALL -find sync -g ORB when the backup is finished.

Splits the paired volume using pairsplit -g ORB
with r/w mode.

Unfreeze DB on opening P-VOL by application.

Resynchronize the paired volume using pairresync
-g ORB.

NOTE:

P-VOL side must stop the WRITE IO to the logical drive corresponding to a [-g name] before
issuing the raidscan -find sync command.

S-VOL side must close the logical drive corresponding to a [-g name] before issuing the
raidscan -find sync

command.

Special facilities for Windows systems

RAID Manager provides the following special facilities for Windows systems:

Signature changing facility for Windows systems (page 188)

GPT disk for Windows (page 191)

Signature changing facility for Windows systems

Consider the following Microsoft Cluster Server (MSCS) configuration in which a MSCS P-VOL is
shared from MSCS Node1 and Node2, and the copied volume of S-VOL is used for backup on
Node2. If the Node2 has reboot on standby state, then MSCS of Node2 has a problem to assign
drive letter of S-VOL with previous P-VOL drive letter. This problem will happen on Node2 on MSCS
environment as shown in the following figure. The conditions are:

Node1 is active.

Node2 is standby state where P-VOL on Node2 is hidden by MSCS, and reboots the Node2.

188 Examples of using RAID Manager commands

Advertising
This manual is related to the following products: