Alarm history script (almh), Alarm history script (alarmhist), Alarmhist usage – HP XP Performance Advisor Software User Manual
Page 41

Alarm history script (ALMH)
This command is now deprecated and does nothing if called. Use the
Alarm history script (ALARMHIST)
command instead.
Alarm history script (ALARMHIST)
This CLUI script provides a command that displays the Alarm History data. Alarm History objects are
created when array usage exceeds a certain user-defined threshold in one of the categories.
ALARMHIST usage
Following is the general format of the command to invoke the script:
alarmhist [-d<delim>] [-L] [-hr] [-ms <URL>] [-auth <user:passwd>] [-dkc
<serial #>]
[-metric <Category>] [-mval <Item Value>] [-st <mm.dd.yyyy hh:mm:ss>]
[-et <mm.dd.yyyy hh:mm:ss>] [-tclass <Time Class>] [-pf <password file>]
Optional arguments:
–ms <management
station>
The URL of the management station.
–auth <user:passwd>
The username and password.
–dkc <Serial Number> Constrains the output by the array serial number.
HP StorageWorks Performance Advisor XP Software command-line user interface user guide