Table 34 – HP StorageWorks XP Remote Web Console Software User Manual

Page 180

Advertising
background image

180 Troubleshooting

A Continuous Access XP Journal error

message is displayed on the Command

View XP management station.

Remove the error cause, and retry the Continuous Access XP Journal

operation.

The status of a logical path is not

normal.

Check the path status in the DKC Status pane, and see

Table 34

.

The pair status is

suspended

.

Check the pair status in the Pairdisplay pane, and see

Table 35

.

Paircreate or pairresync operation

resulted in a timeout error.

If the timeout error was caused by a hardware failure, a SIM is

generated. If this occurs, call you HP account support representative, and

retry Continuous Access XP Journal operations after the problem is

solved.
If no SIM was generated, wait for 5 or 6 minutes, and check the pair

status of the pairs being created or resumed. If the pair status changed

correctly, the failed operation completed after the timeout message was

issued. If the pair status did not change as expected, a heavy workload

might have prevented the Continuous Access XP Journal operation from

completing. In this case, retry the Continuous Access XP Journal

operation when the array has a lighter workload.
If a communications error occurs between the Command View XP

management station and the SVP, see the HP StorageWorks Command

View XP user guide for XP Disk Arrays for instructions.

There is a pinned track on a

Continuous Access XP Journal volume.

See ”

Pinned track recovery for Continuous Access XP Journal volumes”

on page 191

for instructions.

Table 34

Troubleshooting problems with status of logical paths

Pair status

Description

Corrective action

Initialization Failed

Link initialization procedure for the

remote array failed.

Ensure that the local and remote arrays

are connected correctly via cables.
Ensure that you entered the correct

serial number (S/N) of the remote array

and the correct path parameters (for

example, local array port, remote array

port, and controller ID).
Ensure that the topology settings of the

local and remote array ports are

correct.

Communication Time Out

Communication between the local and

remote arrays timed out.

Ensure that the remote array is powered

on, and NVS and cache are fully

functional.
Ensure that the network relay devices

(cables, connectors, switches, ESCDs,

extender devices, communication lines,

and all other devices connected to the

extenders) are properly configured and

functional.
Delete the failed path. You might need

to change the minimum paths setting or

delete the remote array to delete the

path. After deletion finishes, add the

path or remote array.

Table 33

General troubleshooting information for Continuous Access XP Journal (continued)

Error

Corrective action

Advertising